3523 Uppsatser om Frequency inverter control - Sida 1 av 235
Frekvensreglering i det nordiska kraftsystemet
Svenska Kraftnät is (together with the other transmission system operators of the Nordic power system) responsible for keeping balance between the generated and demanded power in the Nordic power system. Spontaneous load variations and system disturbances, however, lead to power imbalance followed by frequency variations. The frequency deviations can be limited to an acceptable level by the spinning reserve, mainly by hydro power control. But there are also other system properties which have a great influence on the frequency and system stability. The frequency and voltage dependence of the loads have a direct influence on the power balance.
KRAV OCH MÖJLIGHETER FÖR STYRNING AV VATTENFALLS VATTENKRAFTSTATIONER
The secondary control must be part of the production plan, since the capacity will bedeployed in advance, just as the primary control. The activation of the new frequencycontrol should be preformed in Vattenfall's operations centers (DC) to minimizecommunication delay. Vattenfall needs to work towards a more holistic optimizationsystem. The main issue for Vattenfall Generation is not how we produce but ratherwhen, which is done with creation of bids. This is where there is the mostopportunity for improvement.
Hur inverkar kontrollbordet på frekvenskurvan vid lyssningsposition i kontrollrummet när placeringar av högtalaren och lyssningsposition placerats efter ITU-R BS.1116-1 rekommendation?
The acoustics in a control room is a complicated phenomenon. Early reflections, reverberation time and area in the room are some of the problems. This report is about the reflection on the mixing console in a control room. The control room being built, these reflections are difficult to take into consideration since the mixing console is one of the very last items you place in the room. This report will explain three main measurements that were done in order to get the answer to the following question: Does the mixing console interfere the frequency curve at listening position? Three measurements were done and the difference between the measurements was that the microphone and the loudspeakers were placed in different places in the control room.
End of line test : En studie av företaget Emotrons linjetestning i produktionen
Emotron is a company specialised in developing, producing and marketing equipment to con-trol, monitor and protect processes and machinery driven by electric motors, with an applica-tion focus. Examples of uses for their products are fans, pumps, lifts and cranes.The project is to look at Emotrons end of line test. The company has seen that at the final test-ing there is a bottleneck that restricts the outflow and prevents an increase in the number of tested products.The purpose of this project is to review how Emotrons end-of-line test works today and if there is a possibility to make the test more efficient in such a way that the quality is not at risk, while increasing the outflow of tested products.The projects first step is to look at and analyse what is causing the bottleneck at the end-of-line. When the analysis is complete, the next step is to review whether there is a possibility to solve the bottleneck and if so in what way can this be done. Emotrons most overall objective of the project is to increase the outflow of the number of tested products without jeopardizing the quality.An analysis has been made on frequency inverters, soft starters and shaft power monitors.
Analys av massapumps- och mixerarbete vid Metsä Board Sverige AB, Husums Fabriker : Energibesparingsåtgärder vid blekeri 4 & 5 med jämförelse mot ny utrustning
Husums plant has a selection of different pulp pumps at bleaching plant 4 and 5. The displacement- (HC-pump, Sund Defibrator PTD-60) and centrifugalpumps (MC-pump, MCA 42-200, MCP 30/20) are of interest in this report. The centrifugal pumps are controlled by throttle valves, which result in an energy loss. Chemical mixers are used to mix ClO2 into the pulp before proceeding into a holding tower where the bleaching process occurs.The energy demand of the different positions has been measured or calculated to be used in comparisons against new equipment. Quotations were requested and delivered from Valmet and Sulzer.
Robothandel ? En rättvis arena? -En litteraturstudie om Robothandeln med aktier
The purpose of the thesis is to demonstrate how high frequency trading affects the stock market. The growing high frequency trading is affecting the game plan on the financial markets and concerns have grown about the high frequency users intentions with their business. It is difficult to receive an overall picture of the subject because the lack of previous research and even the research that exist do not show the entire picture. The thesis contributes to the research through a comprehensive picture of the present debate as well as the previous research through a literature study. Our results showed that high frequency trading provides liquidity to the market, there is a statistical connection between high frequency trading and volatility, no price manipulation is being used and there is a need for a supervision of the high frequency trading..
Styrning av artikelplacering i lager
This thesis deals with the field of warehouse management, focusing on frequency control of stock. The purpose of the thesis is to reduce the warehouse staff mileage by placing an article based on its number of picks, i.e. how frequently it gets picked. In order to achieve relevant results the following four questions have been answered in the thesis: How should the articles be placed with regard to the picking frequency?Which factors, if any, needs to be addressed beyond the picking frequency when articles are placed based on frequency?Can the present picking system be improved?Is frequency placement with regard to the picking frequency profitable to implement for the company?The thesis is based on literature studies and on the data that has been collected from the company?s business system.
Utredning av frekvensregleringens påverkan på mekanisk utrustning i en kaplanturbin
As a consequence of increasing wind power installations in the Nordic grid the last years, the need for regulating power has become larger. In the Nordic grid, regulating power is mainly provided by hydro power. One part of the regulating power is called frequency control, which ensures that the grid frequency is stable and close to 50 Hz.However, setting the turbine into frequency controlled operation may cause stress and wear of the components in the mechanical control system. Frequency controlling implies large and frequent servo forces and longer travelling distance of the sliding bearings in the Kaplan turbine.Based on one selected Kaplan turbine, Selsfors G1, measurements and MATLAB calculations have been performed in order to determine forces and movements of the linkage system. With these forces and movements as input, stresses and fatigue have been determined as well as sliding distances, bearing pressures and wear of bearings during a typical lifetime of 40 years.The results indicate that no severe wear exists on the bearings during 40 years of service.
Förstudie av gränssnitt och styrprogram till SD-180
En av Glimek AB:s mest förekommande maskiner är SD-180 som används för degavvägning. Den finns i flera olika varianter. Den enklaste har enbart start- och stoppknapp och en potentiometer för att ställa hastigheten och en mer avancerad variant har en operatörspanel där olika möjligheter till inställningar finns.Konstruktionen på denna maskin hade inte uppdaterats på många år och behövde en uppdatering av användargränssnitt, programvara och elkonstruktion. Arbetet har framförallt koncentrerat sig på användargränssnittet till panelen.En del av arbetet var att undersöka om det var möjligt att utesluta PLC ur konstruktionen och använda en mer avancerad programmerbar frekvensomformare. Eftersom det blev problem med lanseringen av programvara till frekvensomformaren och enbart en mindre bra fungerande demoversion fanns tillgänglig så var detta tyvärr inte möjligt.I arbetet har olika varianter på operatörspaneler utretts.
Testbänk för motorbåtsdrev
Marinediesel has, to meet there customers needs for a suitable sterndrive to powerboats, developed a prototype. The prototype is currently in the testing phase. The opportunity to test the sterndrive under load inside the workshop has not previously been possible. Until now the drive has been tested in a test bench without any load on the propeller axle. The prototype has also been tested under real conditions mounted on a boat.The idea with my thesis was to create a test bench that can run around the clock in order to be able to test things like wear and service intervals and other things that require that the test interval is long.
Design och implementering av enhandsburen RFID-läsare
Radio frequency identification (RFID) is a versatile wireless technology usedworldwide. The fields of applications are many and its popularity constantlygrows due to smaller in size, better and less expensive components. RFID isused to identify, track or share information about an object using radio waves.This master thesis describes the process of designing and implementing ahandheld UHF RFID reader. The goal was to, based on a UHF RFID-chipdesign a fully functional, small in size and power efficient device. Amicrocontroller provides the user interface and is also used to control theRFID-chip and a Bluetooth device.
Elkvalitéproblem vid varvtalsstyrd motordrift i industrimiljö
Övertoner orsakade av varvtalsstyrda motordrifter ger problem i industrisystem. Syftet med studien är att identifiera problemen och ge rekommendationer för att undvika dem. Studien utfördes som examensjobb på KTH för konsultföretaget Ramböll. En litteraturstudie i ämnet kombinerades med elkvalitémätningar på drifter hos Sandvik Mining.Elkvalitéproblem orsakade av varvtalsstyrda motordrifter kommer till stor del av att frekvensstyrningen ger olinjärt strömuttag som, om nätet inte är tillräckligt starkt, påverkar spänningskvalitén. Problemen kan vara driftstopp, störd utrustning och ökat slitage på utrustning för att nämna några.Denna studie visar att vid ändringar i system innehållande övertoner kan framtida övertonshalter approximeras för vissa fall.
Adaptiv katalysatormodell för reglering
This master?s thesis describes the development of a model of the catalystsystem aiming at control by an MPC. A well functioning model, which is suitable in control purpose, is important while emission legislation become more and more hard to fulfill for the car manufacturers. Much research has been done in the field of physical modeling of the system, but in this work a linear adaptive time discrete ARX-model is developed and validated.The systems tendency to change its dynamic during usage implies that the model must be adaptive. The developed model proved to be well functioning and shows promising conditions for the MPC design.
Aktiv bullerdämpning i ventilationssystem
Active headsets have been on the market for years and now it is time for something else to enter the stage. The technology of active noise reduction can for exmple also be used in ventilation systems for reducing ventilation noise. An active control system principally consists of four important components, namely the downstream error microphone, the upstream detection or reference microphone, the digital signal processor (DSP) and a loudspeaker. The upstream reference microphone listen to the primary ventilation noise and sends it to the DSP which makes a phase shift to the signal and sends it to the loudspeaker. The loudspeaker sends out the opposite waveform of the incoming one and reduce the primary ventilation noise.
Frekvens och spanningsskalning i en inbyggd mikroprocessor; for att mojliggora implementationen av schemalaggning med stod for dynamisk frekvens- och spanningsreglering for energihantering.
Minimizing power consumption is a critical part of many embedded design projects. Thechallenge is to limit the power consumption of the system and at the same time providesatisfactory service to the user. With regards to microprocessors, the main way of limiting powerconsumption during program execution is to adjust the frequency and the voltage at which theprocessor operates.To enable the implementation of real-time scheduling with support for dynamic voltage andfrequency scaling, an exhaustive study of the Freescale i.MX31 embedded microprocessor isperformed. Specifically, the power consumption relationship to all relevant frequency andvoltage settings is investigated. In addition, to enable frequency and voltage scaling in a real-timeenvironment, a complete timing analysis of proposed voltage and frequency scaling methods isperformed and their suitability for use in real-time systems is evaluated.To integrate voltage and frequency scaling capability into OSE RTOS, a software module hasbeen developed for this operating system.